ACTIONTEC ELECTRONICS, INC.

DATALINK V.90 (LUCENT)

Card Type Modem
Chip Set Lucent
Maximum Modem Rate 56Kbps
Maximum Fax Rate 14.4Kbps
Data Modulation Protocol Bell 103A/212A, 103
ITU-T V.21, V.22bis, V.23, V.32, V.32bis, V.34, V.34+, V.90/K56flex
Fax Modulation Protocol ITU-T V.17, V.21CH2, V.27ter, V.29
Error Correction/Compression MNP10,MNP5, V.42, V.42bis
Fax Class Class I & II
Data Bus PCMCIA Type II


55457

SUPPORTED COMMAND SET

Basic AT Commands

AT, ‘+++’, A/
A, C, E, F, H, M, P, Q, T, V, Y, Z
&B, &C, &G, &W

Extended AT Commands

\A, \B, \K, \T, \X

S Registers

S0, S1, S2, S3, S4, S5, S9, S12
Note: See MHI Help File for full command documentation.


Proprietary AT Command Set

AUTO-MODE DETECTION

Type: Configuration
Format: AT [cmds] Nn [cmds]
Description: Selects various options for the automatic detection and negotiation of protocols during the handshake process if the modem is communicating with a remote modem of dissimilar speed.

Command

Function

N0

Selects handshake only for standard indicated in S37 register and B command

N1

In originate mode, handshake begins at line speed designated by the S37 register and B command. Modem can shift to a slower speed if necessary.


AUXILIARY RELAY SELECTION

Type: Configuration
Format: AT [cmds] &Jn [cmds]
Description: Selects auxiliary relay

Command

Function

&J0

Enable auxiliary relay - always on

&J1

Reserved


COMMUNICATION PROTOCOLS

Type: Configuration
Format: AT [cmds] Bn [cmds]
Description: Selects the communication protocol for data calls
Note: The B command allows the simultaneous selection of more than one suffix, enabling multiple protocols.

Command

Protocol

B0

ITU-T V.22 at 300 or 1200bps

B1

Bell 212A at 300 or 1200bps

B2

Disables V.23 reverse channel

B3

Disables V.23 reverse channel

B15

Enables V.21 when modem is running at 300bps

B16

Enables Bell 103J when modem is running at 300bps


COMMUNICATIONS MODE

Type: Configuration
Format: AT [cmds] &Mn [cmds]
Description: Selects communications mode

Command

Mode

&M0

Asynchronous mode

&M1 - &M4

Reserved


COMMUNICATIONS MODE

Type: Configuration
Format: AT [cmds] &Qn [cmds]
Description: Selects communications mode options

Command

Mode

&Q0

Buffered asynchronous mode.

&Q1 - &Q4

Reserved

&Q5

Error control mode.

&Q6

Buffered asynchronous mode.

&Q7

Reserved

&Q8

MNP error control mode.

&Q9

V.42 or MNP error control mode.


CONFIGURATION PROFILES

Type: Immediate
Format: AT [cmds] &Vn [cmds]
Description: Displays report on configuration profiles

Command

Function

&V0

Displays active and stroed configuration profiles


DATA SET READY (DSR)

Type: Configuration
Format: AT [cmds] &Sn [cmds]
Description: Selects DSR options

Command

Function

&S0

DSR forced high

&S1

DSR high only while modem is handshaking or connected


DATA TERMINAL READY (DTR)

Type: Configuration
Format: AT [cmds] &Dn [cmds]
Description: Selects modem response to DTR

Command

Function

 

&D0

Modem does not respond to DTR
 

&D1

Modem goes to command mode on DTR toggle
»

&D2

Modem goes to command mode and disconnects (hangs up) on DTR toggle;

Auto-Answer is disabled on low DTR.

 

&D3

Modem is initialized on DTR toggle


DIAL

Type: Immediate
Format: AT [cmds] D<#> [cmds]
Description: Dials telephone number according to any modifiers included in the string
Note: Any combination of modifiers can be used to produce the desired dial functions in sequence.

Command

Function

DL

Re-dial last number

DP

Pulse dialing enabled

DS=n

Dial stored telephone number n

DT

Tone dialing enabled/Pulse dialing disabled

DW

Dialing resumed following dial tone detection

D,

Dialing paused for amount of time specified in S8 register

D!

Flash function initiated. Modem commanded to go off-hook for specified time before returning on-hook.

D@

Wait for Quite Answer function enabled. Modem waits until a "quiet answer," a ring-back signal followed by silence up to the time specified in S7, is received prior to executing the rest of the dial string.

D$

Wait for prompt tone detection function enabled. Waits for prompt tone for amount of time specified by the S7 command.

D^

Disables data calling tone transmission

D;

Modem returned to idle state after dialing. The semicolon can only be placed at the end of the dial command.


EXTENDED RESULT CODES

Type: Configuration
Format: AT [cmds] Wn [cmds]
Description: Enables selection of additional result codes

Command

Function

W0

Enables CONNECT result codes to report DTE speed.

W1

Enables CONNECT result codes to report DTE speed.

W2

Enables CONNECT result codes to report DCE speed.


FACTORY DEFAULT PROFILE

Type: Configuration
Format: AT [cmds] &Fn [cmds]
Description: Sets values in active profile to values found in the default profile

Command

Function

&F0

Restores factory settings as active configuration


FLOW CONTROL

Type: Configuration
Format: AT [cmds] &Kn [cmds]
Description: Enables flow control options

Command

Function

&K0

Flow control disabled

&K1

Reserved

&K2

Reserved

&K3

RTS/CTS flow control enabled

&K4

XON/XOFF flow control enabled


ON-LINE

Type: Immediate
Format: AT [cmds] On [cmds]
Description: Controls on-line command (data transmission) state options.
Note: The O command must be placed at the end of the command string.

Command

Function

O0

On-line command mode with no retraining enabled

O1

On-line command mode with retraining enabled

O3

On-line command mode after rate renegotiation


PULSE DIALING RATIO

Type: Configuration
Format: AT [cmds] &Pn [cmds]
Description: Selects pulse dial make/break ratio

Command

Function

&P0

39/61ms at 10pps (North America)

&P1

33/67ms at 10pps (Europe)

&P2

39/61ms at 20pps


REPORT INFORMATION

Type: Immediate
Format: AT [cmds] In [cmds]
Description: Displays information requested

Command

Function

I0

Reports modem model and speed

I1

Reports ROM checksum

I2

Tests and reports ROM checksum

I3

Reports default speed and firmware version

I4

Reports firmware version for data pump

I5

Reports board ID - software and hardware version and country code

I6

Reports data connection information

I7

Reports manufacturer and model information

I8

Reports OK

I9

Reports OK

I11

Reports diagnostic information from last modem connection


RESTORE PROFILE ON POWER-UP

Type: Configuration
Format: AT [cmds] &Yn [cmds]
Description: Restores a selected profile into the active profile on power-up (hard reset)

Command

Function

&Y0

Restore profile 0 on power-up

&Y1

Reports ERROR


SELECT CALL PROGRESS RESULT CODES

Type: Configuration
Format: AT [cmds] Xn [cmds]
Description: Enables selection of tone detection and associated result code format options

Command

Function

X0

Busy and dial tone detection disabled; result codes disabled

X1

Busy and dial tone detection disabled; result codes enabled.

X2

Busy tone detection disabled, dial tone detection enabled; result codes enabled.

X3

Busy tone detection enabled, dial tone detection disabled; result codes enabled.

X4

Busy and dial tone detection enabled; result codes enabled.

X5

Busy and dial tone detection enabled; result codes enabled.

X6

Busy and dial tone detection enabled; result codes enabled.

X7

Busy and dial tone detection enabled; result codes disabled


SPEAKER VOLUME

Type: Configuration
Format: AT [cmds] Ln [cmds]
Description: Controls speaker volume

Command

Function

 

L0

Lowest volume setting
 

L1

Low volume setting
»

L2

Medium volume setting
 

L3

Highest volume setting


STORE TELEPHONE NUMBER

Type: Configuration
Format: AT [cmds] &Zn=(phone # & modifiers)
Description: Writes selected telephone numbers into the non-volatile memory at location n
Note: The characters described in the D command are valid for use in the &Z command; telephone numbers and modifiers can include up to 40 characters.


TEST MODES

Type: Immediate
Format: AT [cmds] &Tn
Description: Selects test options

Command

Function

&T0

End current test

&T1

Begin local analog loopback test

&T3

Begin local digital loopback

&T6

Request remote digital loopback


Extended AT Commands

ADJUST BAUD RATE SELECTION

Type: Configuration
Format: AT [cmds] \Jn [cmds]
Description: Controls emulation of modems that force DTE interface to line speed

Command

Function

\J0

Enable emulation

\J1

Disable emulation


BLACKLIST INFORMATION

Type: Configuration
Format: AT [cmds] %B [cmds]
Description: Displays numbers in blacklist


COMPRESSION

Type: Configuration
Format: AT [cmds] %Cn [cmds]
Description: Selects data compression

Command

Function

%C0

Data compression disabled

%C1

V.42 and MNP5 enabled


CONNECT MODE

Type: Configuration
Format: AT [cmds] \Nn [cmds]
Description: Controls the type of connection the modem will operate in

Command

Function

\N0

Buffer mode enabled

\N1

Direct mode enabled

\N2

MNP reliable mode enabled

\N3

V.42/MNP auto-reliable mode enabled

\N4

V.42 error control mode enabled

\N5

V.42/MNP auto-reliable mode enabled

\N7

V.42/MNP auto-reliable mode enabled


EXTENDED RESULT CODES

Type: Configuration
Format: AT [cmds] \Vn [cmds]
Description: Selects extended protocol result codes

Command

Function

\V0

Extended result codes disabled

\V1

Extended result codes enabled

\V2

Extended result codes enabled


FLOW CONTROL

Type: Configuration
Format: AT [cmds] \Gn [cmds]
Description: Selects modem port flow control - dummy command for compatibility

Command

Function

\G0

Report OK

\G1

Reports ERROR


FLOW CONTROL TYPE

Type: Configuration
Format: AT [cmds] \Qn [cmds]
Description: Sets type of flow control used by modem

Command

Function

\Q0

Flow control disabled

\Q1

Bi-directional XON/XOFF flow control enabled

\Q2

CTS flow control by DCE enabled

\Q3

Bi-directional RTS/CTS flow control enabled


RING SIGNAL CONTROL

Type: Configuration
Format: AT [cmds] \Rn [cmds]
Description: Controls ring indicator signal – compatibility command

Command

Function

\R0

Ring indicator signal is off after call is answered


Special AT Commands

DATA CALLING TONE

Type: Configuration
Format: AT [cmds] -Cn [cmds]
Description: Controls data calling tone

Command

Function

-C0

Disable data calling tone

-C1

Enable data calling tone


S(status)-Registers

56K LINE SPEED

Type: Register
Format AT [cmds] S38=n [cmds]
Description: Sets the maximum downstream allowable data exchange rate attempted during handshake process.

Command

Function

S38=0

Disable V.90

S38=1

Set to maximum speed

S38=2

29333bps

S38=3

30666bps

S38=4

32000bps

S38=5

33333bps

S38=6

34666bps

S38=7

36000bps

S38=8

37333bps

S38=9

38666bps

S38=10

40000bps

S38=11

41333bps

S38=12

42666bps

S38=13

44000bps

S38=14

45333bps

S38=15

46666bps

S38=16

48000bps

S38=17

49333bps

S38=18

50666bps

S38=19

52000bps

S38=20

53333bps


AUTO MODE

Type: Register
Format: AT [cmds] S43=n [cmds]
Range: 0-1
Unit: ASCII
Description: Controls auto mode for testing and debugging

Command

Function

S43=0

Disable auto mode

S43=1

Enable auto mode


AUTO RATE

Type: Register
Format: AT [cmds] S42=n [cmds]
Range: 0-1
Unit: ASCII
Description: Controls auto rate for testing and debugging

Command

Function

S42=0

Disable auto rate

S42=1

Enable auto rate


BIT-MAPPED REGISTER S14

Format: AT [cmds] S14=n [cmds]
Range: 0-174
Unit: Bit-mapped
Description: Controls result codes and display and dial mode.

Bit

Value

Function

0 - 2

0

Reserved

3

0

1

Display result codes in numeric format

Display result codes in verbose format

4, 5

0

Reserved

6

0

1

10 pulse dial PPS

20 pulse dial PPS

7

0

Reserved


BIT-MAPPED REGISTER S21

Format AT [cmds] S21=n [cmds]
Range: 0-253
Unit: Bit-mapped
Description: Selects CTS/DCD/DSR signals and low DTR action.

Bit

Value

Function

0 - 2

0

Reserved

4, 3

00

01

10

11

DTR signal ignored

Modem goes to command mode on low DTR

Modem disconnects on low DTR; Auto-Answer is disabled.

Modem is initialized on low DTR

5

0

1

DCD forced high

DCD normal

6 - 7

0

Reserved


BIT-MAPPED REGISTER S22

Format AT [cmds] S22=n [cmds]
Range: 0-255
Unit: Bit-mapped
Description: Controls limits results codes, and pulse dial make/break ratio.

Bit

Value

Function

0 - 3

0

Reserved

6 - 4

000

100

101

110

111

Basic result codes only enabled

Basic and connection speed result codes enabled

Basic and connection speed result codes and dial tone detection enabled

All result codes except dial tone detection enabled

All result codes enabled

7

0

1

33/67ms at 10pps (Europe)

39/61ms at 10pps (North America)


BLIND DIALING DELAY

Type: Register
Format AT [cmds] S6=n [cmds]
Range: 2-65
Unit: 1 second
Description: Duration of delay after modem goes off-hook and before dialing blindly during modes set by X0, X1 or X3 commands.


CARRIER LOSS RESPONSE TIME

Type: Register
Format AT [cmds] S10=n [cmds]
Range: 1-254
Unit: .1 second
Description: Maximum time allowed by the modem after losing the carrier signal and prior to initiating hang-up process.


DATA CALLING TONE

Type: Register
Format: AT [cmds] S35=n [cmds]
Range: 0-1
Unit: ASCII
Description: Controls data calling tone

Command

Function

S35=0

Disables calling tone

S35=1

Enables calling tone


DCE LINE SPEED

Type: Register
Format AT [cmds] S37=n [cmds]
Description: Sets the maximum allowable data exchange rate attempted during handshake process.

Command

Function

S37=0

Set to maximum speed

S37=1

Reserved

S37=2

1200/75bps

S37=3

300bps

S37=4

Reserved

S37=5

1200bps

S37=6

2400bps

S37=7

4800bps

S37=8

7200bps

S37=9

9600bps

S37=10

12.0Kbps

S37=11

14.4Kbps

S37=12

16.8Kbps

S37=13

19.2Kbps

S37=14

21.6Kbps

S37=15

24.0Kbps

S37=16

26.4Kbps

S37=17

28.8Kbps

S37=18

31.2Kbps

S37=19

33.6Kbps


ERROR CORRECTION NEGOTIATION

Type: Register
Format AT [cmds] S36=n [cmds]
Description: Selects the action of the modem if it fails to connect with the error-correction protocol set in &Q.

Command

Function

S36=0, 2

Hang up

S36=1, 3

Attempt asynchronous connection

S36=4, 6

Attempt MNP connection; disconnect (hang up) on MNP fail

S36=5, 7

Attempt MNP connection; fallback to asynchronous connection on MNP fail


ETC STARTUP SELECTION

Type: Register
Format AT [cmds] S40=n [cmds]
Range: 0-2
Unit: ASCII
Description: Controls ETC setting at startup

Command

Function

S40=0

Enable normal autorating

S40=1

Enable 4800 or lower initial rate

S40=2

Enable 9600 or lower initial rate


FEATURE NEGOTIATION OPTIONS

Type: Register
Format: AT [cmds] S48=n [cmds]
Description: Selects active error correction and compression protocols

Command

Function

S48=7

Detection negotiation and XID negotiation enabled

S48=128

Fall-back to options set in S36
Note: The action each variant of S48 causes depends on the setting of S36

S36 Setting

S48=7

S48=128

S36=0, 2

Attempt LAPM or disconnect

Reserved

S36=1, 3

Attempt LAPM or asynchronous

Asynchronous

S36=4, 6

Attempt LAPM, MNP or disconnect

MNP or disconnect

S36=5, 7

Attempt LAPM, MNP or asynchronous

MNP or asynchronous


INACTIVITY TIMER

Type: Register
Format AT [cmds] S30=n [cmds]
Range: 0-255
Unit: 1 minute
Description: Maximum duration of DTE and DCE inactivity allowed prior to initiating hang-up process.
Note: S30=0 disables the timer and allows indefinite inactivity.


LOCAL PHONE STATUS

Type: Immediate
Format: AT [cmds] S90 [cmds]
Description: Displays the status of the local phone

Value

Meaning

0

Local phone is on-hook

1

Local phone is off-hook


NO CARRIER TIME-OUT

Type: Register
Format AT [cmds] S7=n [cmds]
Range: 1-255
Unit: 1 second
Description: Maximum wait time the modem uses after dialing to detect a carrier signal from the remote modem for both originating and answering calls.
Note: W dial modifier also uses S7 to set the maximum time to wait.


PAUSE DURATION

Type: Register
Format AT [cmds] S8=n [cmds]
Range: 0-65
Unit: 1 second
Description: Duration of pause per comma (,) command used in a command or dial string


PROTOCOL OPTIONS

Type: Register
Format AT [cmds] S109=n [cmds]
Range: 0-2
Unit: ASCII
Description: Designates the carrier speeds available for the V.34, K56flex and V.90 protocols during handshake, retrain, and speed re-negotiations.

Command

Function

S109=0

Disables all 56K connections

S109=1

Attempt K56flex; then V.90 connection

S109=2

Enable V.90; disable K56flex


SLEEP MODE TIMER

Type: Register
Format: AT [cmds] S89=n [cmds]
Range: 0, 5-255
Unit: 1 second
Description: Controls amount of time modem waits in off-line command mode before entering standby mode

Command

Function

S89=0

Disable standby mode


SLEEP TIMER

Type: Register
Format AT [cmds] S24=n [cmds]
Range: 0,5-255
Unit: 1 second
Description: Maximum duration of DTE and DCE inactivity allowed prior to initiating low-power sleep mode.


SYNTHETIC RING FREQUENCY

Type: Register
Format: AT [cmds] S33=n [cmds]
Range: 0-5
Unit: ASCII
Description: Controls frequency of synthetic ring

Command

Function

S33=0

Disable synthetic ring

S33=1 - 5

Sets ring frequency to range 1 - 5, respectively


SYNTHETIC RING VOLUME

Type: Register
Format: AT [cmds] S32=n [cmds]
Range: Unidentified
Unit: ASCII
Description: Controls volume of synthetic ring, in db


TONE PULSE DURATION

Type: Register
Format AT [cmds] S11=n [cmds]
Range: 50-150
Unit: 1 ms
Description: DTMF tone pulse duration and time between tone pulses for tone dialing operations.


TRANSMISSION LEVEL

Type Register or Configuration
Format AT [cmds] S91=n [cmds]
Range 6-15
Unit -1 dBm
Description Sets the signal level for transmission over leased-lines
Note: Command is only effective in Japan


TRANSMISSION LEVEL - DIRECT CONNECT

Type Register or Configuration
Format AT [cmds] S92=n [cmds]
Range Unidentified
Unit -1 dBm
Description Sets the signal level for transmission over a direct connect


V.34 MODULATION

Format AT [cmds] S28=n [cmds]
Range: 0-255
Unit: ASCII
Description: Controls V.34 modulation

Command

Function

S28=0

Disables V.34 modulation

S28=1 - 255

Enables V.34 modulation