B&B ELECTRONICS

1140 (v.54 MODEM) ST

Card Type

Transceiver

NIC Type

Unidentified

Boot ROM

Not available

Network Transfer Rate

57.6Kbps

Topology

Peer-Peer

Wiring Type

Fiber optic cable

Data Bus

External

CONNECTIONS

Function

Label

Function

Label

Fiber Optic Connector (ST)

CN1

RS-232 (DCE or DTE)

CN3

Fiber Optic Connector (ST)

CN2

   


USER CONFIGURABLE SETTINGS

Function

Label

Position

»

Asynchronous mode

SW1/7

On

 

Synchronous mode

SW1/7

Off

»

Carrier control constantly on

SW1/8

Off

 

Carrier control controlled by RTS

SW1/8

On

»

Extended Signaling Rate set to -2.5% to +1% Basic

SW2/3

Off

 

Extended Signaling Rate set to -2.5% to +2.3% Extended

SW2/3

On

»

Factory configured - do not alter

SW2/6

Unidentified

»

Factory configured - do not alter

SW2/7

Unidentified

»

V.54 Loopback test enable

SW2/8

Off

 

V.54 Loopback test disable

SW2/8

On

 

Local analog Loopback (LAL) test

SW3

Up

 

Remote digital Loopback (RDL) test

SW3

Down

 

V.54 bit error rate (BER) test, transmit "511" test pattern

SW4

Up

 

V.54 bit error rate (BER) test, transmit "511/E" test pattern (with errors)

SW4

Down


NETWORK SPEED SELECTION

Speed

SW1/1

SW1/2

SW1/3

SW1/4

 

1.2Kbps

On

On

On

On

 

1.8Kbps

Off

On

On

On

 

2.4Kbps

On

Off

On

On

 

3.6Kbps

Off

Off

On

On

 

4.8Kbps

On

On

Off

On

 

7.2Kbps

Off

On

Off

On

»

9.6Kbps

On

Off

Off

On

 

14.4Kbps

Off

Off

Off

On

 

19.2Kbps

On

On

On

Off

 

28.8Kbps

Off

On

On

Off

 

38.4Kbps

On

On

Off

Off

 

57.6Kbps

Off

On

Off

Off


CLOCK SOURCE

Setting

SW1/5

SW1/6

»

Internal transmit clock

On

On

 

Receive recover clock

Off

On

 

External transmit clock

On

Off


WORD LENGTH

Setting

SW2/1

SW2/2

 

8 bits

Off

On

 

9 bits

On

On

»

10 bits

Off

Off

 

11 bits

On

Off


RTS/CTS DELAY

Setting

SW2/4

SW2/5

»

7 ms

On

On

 

53 ms

Off

On

 

No delay

On

Off

 

No delay

Off

Off


DIAGNOSTIC LED(S)

LED

Color

Status

Condition

LED1

Red

Blinking

Errors are present during "511" test

LED1

Red

Off

No errors are present during "511" test

LED1

Red

On

"511/E" test is successful

LED2

Unidentified

On

LAL test activated

LED2

Unidentified

Off

LAL test not activated


MISCELLANEOUS TECHNICAL NOTES

NOTE: Model 1140 is available with either male or female DB-25 connector. Model 1140 is available

with either SMA or ST fiber optic connectors.

NOTE: Model 1140 is designed to work in pairs.